Mechanics/electronics
Supply voltage Vs DC 10 V … 30 V, reverse polarity protected UV ≥ DC 24 V for devices with heating
Ripple 5 Vpp 1) Power consumption Typ. 3 W Initialization time 500 ms Housing material Metal (Aluminum die cast) Window material Glass Connection type Male connector, M12, 5-pin Weight 1,000 g Dimensions (W x H x D) 69 mm x 50 mm x 153 mm Enclosure rating IP65 Protection class II 2) - 1) May not fall short of or exceed VS tolerances.
- 2) Reference voltage DC 32 V.
-
Performance
Measuring range 0.2 m … 30 m, 90 % remission 1) 2) 0.8 m … 15 m, 6 % remission 1) 2)
Target Natural objects Resolution 12 bit Repeatability 1 mm 3) 4) Accuracy ± 3 mm Response time 250 ms Output time 250 ms Light source Laser, red 5)
visible red lightLaser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) Typ. light spot size (distance) 10 mm (at 7 m) 45 mm (at 30 m)
100 mm (at 70 m)
- 1) In ambient light, max. 1 klx of constant light.
- 2) Unique up to 150 m.
- 3) 6 % … 90 % remission.
- 4) Statistical error 1 σ.
- 5) Average service life of 50,000 h at TA = +25 °C.
-
Interfaces
Analog output Number 1 Type Current output Current 0 mA … 20 mA 1) Multifunctional input (MF) > 12 V 2) Laser-off input > 12 V - 1) Can be configured to the device: 0 mA … 20 mA / 4 mA … 20 mA (max. load resistance = Uv-2 V / 0.0205 A).
- 2) Refer to function MF input.
-
Ambient data
Electromagnetic compatibility (EMC) EN 61000-6-2, EN 55011 EN 60947-5-7: 2003-9
Ambient temperature, operation –10 °C … +45 °C –10 °C … +75 °C, operation with cooling case
Ambient temperature, storage –25 °C … +75 °C Temperature drift Typ. 0.05 mm/K Typ. Ambient light immunity ≤ 3,000 lx Mechanical load Shock: (EN 600 68-2-27 / –2-29) Sine: (EN 600 68-2-6)
Noise: (EN 600 68-2-64)
Reviews