| Features | |
| Reading field: | Side |
| Focus: | Adjustable focus |
| Sensor: | CMOS matrix sensor, gray scale values |
| Sensor resolution: | 752 px x 480 px (WVGA) |
| Focal length: | 7 mm |
| Code resolution: | ≥0.1 mm 1) |
| Reading distance (at code resolution): | 40 mm … 1,500 mm (2.6 mm) 2) |
| Scanning frequency: | 25 Hz, WVGA resolution |
| Internal lighting: | Red |
| Light source: | Lighting LEDs: visible red light (λ = 617 ± 15 nm) feedback spot: visible green light (λ = 525 ± 15 nm) |
| LED class: | 1 (IEC 62471 (2006-07) / EN 62471 (2008-09)), radiance LB < 10 kW/(m²sr) within 100 s, LR < 28/α kW/(m²sr) within 10 s at distance > 200 mm |
| MTBF: | 75,000 h |
| 1) 2) Valid for Data Matrix, PDF417 and 1D codes with good printing quality | |
| Performance | |
| Bar code types: | Interleaved 2 of 5, Codabar, Code 128, Code 32, Code 39, Code 93, GS1 DataBar, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN |
| 2D code types: | Data Matrix ECC200, GS1 Data-Matrix, PDF417, PDF417 Truncated, QR code |
| No. of codes per reading interval: | 1 … 50 |
| No. of characters per reading interval: | 500 (for multiplexer function in CAN operation) |
| Transport speed: | ≤2 m/s |
| Internal image storage: | 135 MB |
| Interfaces | |
| Function (Serial (RS-232, RS-422)): | Host, AUX |
| Data transmission rate (Serial (RS-232, RS-422)): | 300 Baud … 115.2 kBaud, AUX: 57.6 kBaud (RS-232) |
| Remark (USB): | USB 2.0 |
| Ethernet: | – |
| Protocol (Ethernet): | PROFINET (optional via external connection module CDM), EtherCAT (optional via external connection module CDF600) |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer/Server) |
| Data transmission rate (CAN bus): | 20 kbit/s … 1 Mbit/s |
| Protocol (CAN bus): | CANopen, CSN (SICK CAN Sensor Network) |
| Remark (PROFIBUS DP): | Optional via external connection module (CDF) |
| DeviceNet: | – |
| Acoustic indicators: | Beeper/buzzer (can be switched off, can be assigned a function to signal a result) |
| Control elements: | 2 buttons (choose and start/stop functions) |
| Optical indicators: | 16 LEDs (5 x status display, 10 x LED bar graph, 1 green feedback spot) |
| Switching inputs: | 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB620/CDM420) |
| Switching outputs: | 4 (“Result 1”, “Result 2”, 2 outputs via optional CMC600 in CDB620/CDM420) |
| Reading pulse: | Auto pulse, CAN, Non-powered, Presentation mode, Switching inputs, Serial interface |
| Configuration software: | SOPAS |
| Mechanics/electronics | |
| Operating voltage: | 10 V DC … 30 V DC |
| Power consumption: | Typ. 3 W |
| Electrical connection: | 1 15-pin D-Sub HD male connector (0.9 m) |
| Housing: | Die-cast aluminum |
| Housing color: | Light blue (RAL 5012) |
| Weight: | 170 g |
| Dimensions: | 71 mm x 43 mm x 35.6 mm 1) |
| Enclosure rating: | IP 65 (EN 60529 (1991-10), EN 60529/A2 (2002-02)) |
| Protection class: | III |
| Lens: | Integrated |
| 1) Swivel connector is 17.8 mm longer | |
| Ambient data | |
| Electromagnetic compatibility (EMC): | EN 61000-6-2 (2006-03) / EN 61000-6-2 (2009-05) |
| Vibration resistance: | EN 60068-2-6 (2008-02) |
| Shock resistance: | EN 60068-2-27 (2009-05) |
| Electrical safety: | EN 60950-1 (2006-04) / EN 60950-1/A11 (2009-03) |
| Ambient operating temperature: | 0 °C … +50 °C |
| Storage temperature: | -20 °C … +70 °C |
| Permissible relative humidity: | 90 %, non-condensing |
| Ambient light safety: | 2,000 lx, on code |
Products specifications
| Manufacturer category | Sick ICR620 |
| Manufacturer | Sick |








Reviews