Technical Data Sheet: KROHNE OPTISWIRL 4070/C
1. Core Identification
-
Manufacturer: KROHNE Messtechnik GmbH (Duisburg, Germany)
-
Model: OPTISWIRL 4070/C (Compact version)
-
Serial Number (SN): D100000001655073
-
Year of Manufacture (MD): 2010
-
Measuring Principle: Karman vortex street (Vortex shedding technology)
2. Process Specifications
| Parameter | Specification (from label) |
| Nominal Size & Pressure | DN50 PN40 (50mm pipe, 40 bar max) |
| Medium / Software | Saturated Steam (Sattdampf) |
| Density (approx.) | $3.77223 \text{ kg/m}^3$ |
| Operating Temperature | $166.2^\circ C$ (at reference point) |
| Operating Pressure | 6.2 bar ü (gauge) |
| Max. Temperature ($TS$) | $240^\circ C$ ($464^\circ F$) |
| Max. Pressure ($PS$) | 40 bar |
| Test Pressure ($PT_{max}$) | 76 bar |
3. Electrical & Signal Data
-
Supply Voltage ($U$): 14…36 VDC
-
Output Signal: 4…20 mA (HART protocol)
-
K-factor: 9089.46 Pulse/m³
-
Technology: 2-wire technology with integrated pressure and temperature compensation
4. Materials & Construction
-
Sensor/Wetted Parts: 1.4435 (316L Stainless Steel)
-
Gasket/O-ring: FPM
-
Housing: Aluminum (Blue/Silver)
-
Protection Class: IP66/67
Installation Highlights
-
Integrated Compensation: This specific unit is configured for “Sattdampf” (Saturated Steam). It uses its built-in temperature and pressure sensors to provide direct mass flow measurement.
-
Flow Direction: Ensure the meter is installed with the flow matching the arrow on the sensor body.
-
Straight Runs: For optimal accuracy, maintain a minimum inlet run of $20 \times DN$ and an outlet run of $5 \times DN$.