EPE-Filter Differential Pressure Indicator
Manufacturer: EPE-Filter (Ketsch, Germany)
Type: Electrical Clogging Indicator (WE)
1. General Description
This device is an electrical differential pressure indicator (clogging indicator) manufactured by EPE-Filter (now part of the Bosch Rexroth group / Kensch). It is designed to monitor the contamination level of hydraulic filters.
The device measures the pressure drop across a filter element. When the pressure drop exceeds a preset limit (indicating the filter is clogged), the internal switch activates, sending an electrical signal to a control system to trigger a maintenance alarm. This unit features a robust aluminum housing capable of withstanding high operating pressures up to 400 bar.
Key Features 🎯
-
High Pressure Rating: Suitable for hydraulic systems with operating pressures up to 400 bar.
-
Universal Switching: Features a changeover contact (SPDT), allowing for flexible wiring (Normally Open or Normally Closed).
-
High Voltage Compatibility: Can switch voltages up to 220 V.
-
Dual Indication Options: The label indicates options for “WO” (Visual) and “WE” (Electrical). This specific unit is equipped with the electrical connector for remote monitoring.
2. Technical Specifications
Performance Data
| Parameter | Value |
| Max. Operating Pressure (Betriebsdr.) | 400 bar |
| Switching Pressure (Schaltdr.) | 1.5 bar or 4.2 bar (Model dependent – check specific unit marking) |
| Function | Differential Pressure Monitoring |
| Media | Hydraulic Oil, Lubricants |
Electrical Data
| Parameter | Value |
| Switch Type | Umschalter (Changeover / SPDT) |
| Switching Voltage | 0 … 220 V (AC/DC) |
| Max. Switching Current | 0.5 A |
| Max. Load / Power | 10 W / 30 VA |
| Connector | DIN 43650 (Valve Plug Style) |
Mechanical Data
| Parameter | Value |
| Housing Material | Aluminum / Steel |
| Process Connection | Threaded (for insertion into filter housing) |
| Seal | O-Ring |
3. Wiring Diagram
The label provides a specific pin-to-color mapping for the electrical connection.
-
Pin 1 (sw / Black): Common (COM)
-
Pin 2 (br / Brown): Normally Closed (NC)
-
Pin 3 (bl / Blue): Normally Open (NO)
Operation Logic:
-
Normal State (Clean Filter): Circuit between Pin 1 (Black) and Pin 2 (Brown) is CLOSED.
-
Alarm State (Clogged Filter): When pressure drop exceeds the setpoint (e.g., 4.2 bar), the switch activates. Pin 1 connects to Pin 3 (Blue), signaling the alarm.
Meta Description Options
Option 1 (SEO-focused):
Datasheet for EPE-Filter electrical clogging indicator. Specs: 400 bar max pressure, 220V/0.5A SPDT switch, for monitoring hydraulic filter status.
Option 2 (Concise):
EPE-Filter Ketsch differential pressure switch datasheet. 400 bar operating pressure, changeover contact, 10W/30VA rating.
Option 3 (Application):
Technical data for EPE hydraulic filter indicator. Learn about this 400 bar differential pressure switch with SPDT output for detecting clogged filters.






Reviews
There are no reviews yet.